{"id":3401,"date":"2022-02-12T00:54:50","date_gmt":"2022-02-11T18:54:50","guid":{"rendered":"http:\/\/www.genesistrading.biz\/?page_id=3401"},"modified":"2022-02-12T01:01:24","modified_gmt":"2022-02-11T19:01:24","slug":"radio-frequency-amplifier","status":"publish","type":"page","link":"https:\/\/www.unimed.com.bd\/index.php\/radio-frequency-amplifier\/","title":{"rendered":"Radio-Frequency Amplifier"},"content":{"rendered":"[vc_row][vc_column][vc_single_image image=&#8221;3404&#8243; img_size=&#8221;full&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<h1><span style=\"color: #ff6600;\">Radio-Frequency Amplifier<\/span><\/h1>\n<h2>With radio-frequency and power electronics technology we contribute to customers&#8217; high performance and efficiency improvement needs.<\/h2>\n<h2><span style=\"color: #ff6600;\">Key Features<\/span><\/h2>\n<ul>\n<li>The lineup of the frequency band (12.77 MHz\uff5e21.29 MHz) and rated output level (1 kW \uff5e 5 kW)<br \/>\ncorresponding to each magnetic field (0.3 T\uff5e 0.5 T).<\/li>\n<li>High linearity and a low noise<\/li>\n<li>UL and IEC standard<\/li>\n<\/ul>\n[\/vc_column_text][vc_column_text]\n<h2>Specifications<\/h2>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<table class=\"table border-bottom\">\n<tbody>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Tesla<\/th>\n<th class=\"bg-gray1\">0.3T<\/th>\n<th class=\"bg-gray1\">0.35T<\/th>\n<th class=\"bg-gray1\">0.4T<\/th>\n<th class=\"bg-gray1\">0.5T<\/th>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Operation Frequency (*1)<\/th>\n<td>12.77MHz<\/td>\n<td>14.90MHz<\/td>\n<td>17.00MHz<\/td>\n<td>21.29MHz<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Frequency Range<\/th>\n<td colspan=\"4\">&lt; +\/-200kHz<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" rowspan=\"3\">Peak Output Power<\/th>\n<th class=\"bg-gray1 tbl-left-header\">4ch<\/th>\n<td colspan=\"4\">1.25kW x 4 (Total 5kW)<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\">2ch<\/th>\n<td colspan=\"4\">2.5kW x 2 (Total 5kW)<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\">1ch<\/th>\n<td colspan=\"4\">5kW<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Cooling<\/th>\n<td colspan=\"4\">Air<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">RF Input<\/th>\n<td colspan=\"4\">0dBm x1<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Impedance<\/th>\n<td colspan=\"4\">50ohm<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">VSWR<\/th>\n<td colspan=\"4\">4.0:1 or less<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Gain<\/th>\n<td colspan=\"4\">61dB(4ch)\/ 64dB(2ch)\/ 67dB(1ch)<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Average Power<\/th>\n<td colspan=\"4\">250W<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Max Gate On Time<\/th>\n<td colspan=\"4\">60msec<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Max Gate On Duty<\/th>\n<td colspan=\"4\">50% maximum for low output power<br \/>\n15% maximum @ Rated output power<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Gain Linearity<\/th>\n<td colspan=\"4\">\u00b11.0dB or less(50\u03a9)<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Phase Linearity(between ch1 and ch2)<\/th>\n<td colspan=\"4\">0 \u00b1 5 degrees<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Droop (Pulse Wide = 3.5msec)<\/th>\n<td colspan=\"4\">\uff0d<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Harmonics<\/th>\n<td colspan=\"4\">-30 dBc or less (50\u03a9)<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Output Noise Power &lt;Blanked&gt;<br \/>\n(Center Frequency +\/-200kHz)<\/th>\n<td colspan=\"4\">-160dBm\/Hz or less<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Interface<\/th>\n<td colspan=\"4\">RS422 conforming<br \/>\nTTL(Gate Signal)<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" colspan=\"2\">Main Voltage<\/th>\n<td colspan=\"4\">single phase AC 220V \u00b110%<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\" rowspan=\"3\">Dimension<\/th>\n<th class=\"bg-gray1 tbl-left-header\">Height<\/th>\n<td colspan=\"4\">177mm<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\">Depth<\/th>\n<td colspan=\"4\">567mm<\/td>\n<\/tr>\n<tr>\n<th class=\"bg-gray1 tbl-left-header\">Width<\/th>\n<td colspan=\"4\">478mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<h2><span style=\"color: #ff6600;\">Precautions on handling products<\/span><\/h2>\n<ul>\n<li>If you wish to purchase and use any of the products and\/or technologies shown in this site, please read the applicable individual technical material or delivery specifications and observe the instructions.<br \/>\nWhen designing and producing equipment or products using any of the products shownin this site, please pay full attention to safety, based on a thorough understanding of the nature and characteristics of the product.<\/li>\n<li>If you intend to use any of the products or technologies shown in this site for any products whose failure or malfunction could directly threaten human life or endanger people, or for any products whose failure could trigger major property damage (such as products in the fields of nuclear power, aerospace, transportation, medicine and safety devices), make sure to consult our customer-relations desk.<br \/>\nWe will not be held responsible for any damage that may arise due to use of such products or technologies of ours without consultation with us.<\/li>\n<li>The products and technologies shown in this site include those whose export or provision to outside of Japan is controlled under the Foreign Exchange and Foreign Trade Control Law of Japan.<\/li>\n<li>The products and technologies shown in this site include those which are controlled under the export control rules of the U.S.A., and require a permit from the US Government, depending on the export destination, if they are to be exported outside of Japan.<\/li>\n<li>The technical information shown in this site is only for explaining typical actions and applications of the products. It does not constitute any guarantee or license related to the intellectual property rights of our company and\/or third parties for use of the products.<\/li>\n<li>The contents of this site are subject to change without notice, in line with technological progress.<\/li>\n<\/ul>\n[\/vc_column_text][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_single_image image=&#8221;3404&#8243; img_size=&#8221;full&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Radio-Frequency Amplifier With radio-frequency and power electronics technology we contribute to customers&#8217; high performance and efficiency improvement needs. Key Features The lineup of the frequency band (12.77 MHz\uff5e21.29 MHz) and rated output level (1 kW \uff5e 5 kW) corresponding to each magnetic field (0.3 T\uff5e 0.5 T). High linearity and a low noise UL and IEC standard [\/vc_column_text][vc_column_text] Specifications [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Tesla 0.3T 0.35T 0.4T 0.5T Operation Frequency (*1) 12.77MHz 14.90MHz 17.00MHz 21.29MHz Frequency Range &lt; +\/-200kHz Peak Output Power 4ch 1.25kW x 4 (Total 5kW) 2ch 2.5kW x 2 (Total 5kW) 1ch 5kW Cooling Air RF Input 0dBm x1 Impedance 50ohm VSWR 4.0:1 or less Gain 61dB(4ch)\/ 64dB(2ch)\/ 67dB(1ch) Average Power 250W Max Gate On Time 60msec Max Gate On Duty 50% maximum for low output power 15% maximum @ Rated output power Gain Linearity \u00b11.0dB or less(50\u03a9) Phase Linearity(between ch1 and ch2) 0 \u00b1 5 degrees Droop (Pulse Wide = 3.5msec) \uff0d Harmonics -30 dBc or less (50\u03a9) Output Noise Power &lt;Blanked&gt; (Center Frequency +\/-200kHz) -160dBm\/Hz or less Interface RS422 conforming TTL(Gate Signal) Main Voltage single phase AC 220V \u00b110% Dimension Height 177mm Depth 567mm Width 478mm [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text] Precautions on handling products If you wish to purchase and use any of the products and\/or technologies shown in this site, please read the applicable individual technical material or delivery specifications and observe the instructions. When designing and producing equipment or products using any of the products shownin this site, please pay full attention to safety, based on a thorough understanding of the nature and characteristics of the product. If you intend to use any of the products or technologies shown in this site for any products whose failure or malfunction could directly threaten human life or endanger people, or for any products whose failure could trigger major property damage (such as products in the fields of nuclear power, aerospace, transportation, medicine and safety devices), make sure to consult our customer-relations desk. We will not be held responsible for any damage that may arise due to use of such products or technologies of ours without consultation with us. The products and technologies shown in this site include those whose export or provision to outside of Japan is controlled under the Foreign Exchange and Foreign Trade Control Law of Japan. The products and technologies shown in this site include those which are controlled under the export control rules of the U.S.A., and require a permit from the US Government, depending on the export destination, if they are to be exported outside of Japan. The technical information shown in this site is only for explaining typical actions and applications of the products. It does not constitute any guarantee or license related to the intellectual property rights of our company and\/or third parties for use of the products. The contents of this site are subject to change without notice, in line with technological progress. [\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/pages\/3401"}],"collection":[{"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/comments?post=3401"}],"version-history":[{"count":3,"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/pages\/3401\/revisions"}],"predecessor-version":[{"id":3406,"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/pages\/3401\/revisions\/3406"}],"wp:attachment":[{"href":"https:\/\/www.unimed.com.bd\/index.php\/wp-json\/wp\/v2\/media?parent=3401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}